Interspeed Ultra
Antifouling
High Strength Hard Antifouling
    PRODUCT DESCRIPTION
    Offers protection in the highest fouling conditions where a hard, scrubbable antifouling is required. Ideal for fast powerboats.
    * High strength, hard antifouling
    * Hard, scrubbable finish to allow clean-off if needed
    * Suitable for burnishing to provide a smooth finish
    * Smooth finish for maximum slip through the water
    * Contains Biolux® technology for sustained antifouling protection

    PRODUCT INFORMATION
    Colour YBA303-Dover White, YBA323-Green, YBA331-Light Blue, YBA333-Blue, YBA341-Red, YBA353-Navy, YBA363-Grey, YBA366-Princess Grey, YBA393-Black Please check availability of full colour range. Not all colours are available in every country.
    Finish Matt
    Specific Gravity 1.5
    Volume Solids 45% average
    Typical Shelf Life 2 yrs
    VOC (As Supplied) 485 g/lt
    Unit Size 750 ml 2.5 Lt

    DRYING/OVERCOATING INFORMATION
    Drying
      5°C 15°C 23°C 35°C
     
    Touch Dry [ISO] 1hrs 45mins 30mins 20mins
    Immersion 24hrs 12hrs 8hrs 6hrs


    Note:Max. Immersion Times are as follows: 5-15°C - 3 mths; 23°C - 2 mths; 35°C - 1 mth
    Overcoating
    Substrate Temperature
    5°C 15°C 23°C 35°C
    Overcoated By Min Max Min Max Min Max Min Max
     
    Interspeed Ultra  16hrs  ext  10hrs  ext  6hrs  ext  4hrs  ext
    Micron 66  16hrs  ext  10hrs  ext  6hrs  ext  4hrs  ext
    Micron Extra (Professional)  16hrs  ext  10hrs  ext  6hrs  ext  4hrs  ext


    APPLICATION AND USE
    Preparation PREVIOUSLY ANTIFOULED SURFACE:
    In Good Condition: Rinse with fresh water and allow to dry. If old antifouling is incompatible or unknown, seal with Primocon.
    In Poor Condition: Use Interstrip to remove all traces of antifouling.
    PRIMING: All preparation for bare substrates is covered on the appropriate primer datasheet.
    BARE GRP: Gelshield 200 for osmosis protection, or Primocon.
    STEEL/IRON: Prime with Interprotect or Primocon.
    LEAD: Etch Primer followed by Interprotect or Primocon.
    WOOD: Preserve, if required, with Intertox. Prime with Interprotect or Primocon.


    Method Apply two coats per season.


    Hints Mixing Stir well before use.
    Thinner YTA085 Thinners No.3
    Thinning Thinning is not recommended.
    Cleaner YTA085 Thinners No.3
    Other True colour will develop after immersion. Take care to apply all the paint calculated even if it means applying an extra coat. It is important for performance to apply the correct thickness.


    Some Important Points To prevent premature failure, ensure the correct amount of paint is applied using the coverage as a guide. Product temperature should be minimum -5°C and maximum 35°C. Ambient temperature should be minimum -5°C and maximum 35°C. Substrate temperature should be minimum 1°C above dew point and maximum 35°C.


    Compatibility/Substrates GRP, Wood, Steel/Iron, Lead. Not suitable for use over Aluminium/Alloy substrates or zinc sprayed surfaces. Can be applied direct over most types of antifoulings, provided they are in sound condition.


    Number of Coats 2-3 by brush/roller


    Coverage (Theoretical) - 10.50 (m²/lt) by brush

    (Practical) - 9.40 (m²/lt) by brush


    Recommended DFT 43 microns dry
    Recommended WFT 96 microns wet


    Application Methods Brush, Roller , AIRLESS SPRAY NOT RECOMMENDED

    TRANSPORTATION,STORAGE AND SAFETY INFORMATION
    Storage GENERAL INFORMATION:
    Exposure to air and extremes of temperature should be avoided. For the full shelf life of Interspeed Ultra to be realised ensure that between use the container is firmly closed and the temperature is between 5°C/40°F and 35°C/95°F. Keep out of direct sunlight.
    TRANSPORTATION:
    Interspeed Ultra should be kept in securely closed containers during transport and storage.

    Safety GENERAL: Contains biocides. Antifoulings should only be wet sanded. Never dry sand or burn-off old antifoulings. Read the label safety section for Health and Safety Information, also available from our Technical Help Line.

    DISPOSAL: Do not discard tins or pour paint into water courses, use the facilities provided. It is best to allow paints to harden before disposal.
    Remainders of Interspeed Ultra cannot be disposed of through the municipal waste route or dumped without permit. Disposal of remainders must be arranged for in consultation with the authorities.

    IMPORTANT NOTES



    The information given in this sheet is not intended to be exhaustive. Any person using the product without first making further written enquiries as to the suitability of the product for the intended purpose does so at their own risk and we can accept no responsibility for the performance of the product or for any loss or damage (other than death or personal or injury resulting from negligence) arising out of such use. The information contained in this sheet is liable to modification from time to time in the light of experience and our policy of continuous product development.
    Please refer to your local representative or visit www.yachtpaint.com for further information.  
    , International, the AkzoNobel logo and other products mentioned in this publication are trademarks of, or licensed to Akzo Nobel. ©Akzo Nobel 2009. Ref:
    Issue Date:
    Supersedes:
    05000059
    20-Sep-2009
    21-Aug-2009